Mechanical Boiler Feed Pump
Flow: 3.7-1350m ³/ h
Lift: 49-1800m
Power: 3-1120kw
Speed: 1450-2950-1750-3500r/ min
Caliber: φ 50- φ200
Temperature range: ≤ 105 ℃
Working pressure: ≤ 3.0MPa
Product Introduction
Mechanical Boiler Feed Pump – High-Quality and Reliable Solution for Your Business Needs
The Mechanical Boiler Feed Pump is an important piece of equipment used in various industries such as power generation, chemical plants, and refineries. This pump is an essential component that is needed to provide water and feed to boilers, which is essential for the production of steam, heat, and power. As a manufacturer located in China, we offer high-quality and reliable mechanical boiler feed pumps that can meet your business needs.
Features and Benefits of Mechanical Boiler Feed Pump
Our Mechanical Boiler Feed Pumps are designed with a range of features that make them suitable for use in different industries. Some of the features of our Mechanical Boiler Feed Pumps include:
1. Durability – Our Mechanical Boiler Feed Pumps are designed to withstand harsh conditions and are built to last for years. These pumps are made with high-quality materials that provide the necessary strength and durability to handle any challenges that may come their way.
2. Efficiency – Our Mechanical Boiler Feed Pumps are designed to provide optimal performance in terms of efficiency, flow rate, and discharge pressure. They are also designed with low NPSH (Net Positive Suction Head) requirements, which helps to reduce the risk of cavitation.
3. Compactness – Our Mechanical Boiler Feed Pumps are compact in size, which makes them easier to install in tight spaces. This also makes them ideal for use in smaller power plants, as they don’t require a lot of space.
4. Low Maintenance – Our Mechanical Boiler Feed Pumps are designed to require minimal maintenance, which helps to reduce downtime and the cost of repairs.
Applications of Mechanical Boiler Feed Pump
Our Mechanical Boiler Feed Pumps are ideal for use in a wide range of applications, including:
1. Power Generation – Our pumps are used to supply water and feed to boilers in power plants, which are essential for the production of steam and electricity.
2. Chemical Plants – Our pumps are used to supply chemicals to reactors in chemical plants, which are used in the production of various chemicals.
3. Refineries – Our pumps are used to supply crude oil to refineries, which is then processed into various petroleum products.
Why Choose Our Mechanical Boiler Feed Pump
There are various reasons why you should choose our Mechanical Boiler Feed Pumps. Some of the reasons include:
1. Quality – Our pumps are designed with high-quality materials, which make them robust and durable.
2. Reliability – Our pumps are reliable and can handle even the toughest conditions.
3. Cost-Effective – Our pumps are cost-effective and offer value for money.
4. Customization – We offer customized solutions to meet the specific needs and requirements of our clients.
5. Easy Installation – Our pumps are easy to install, which reduces the time and cost of installation.
Final Words
In conclusion, our Mechanical Boiler Feed Pumps are high-quality and reliable solutions that can meet your business needs. With features such as durability, efficiency, compactness, and low maintenance, our pumps are ideal for use in various applications such as power generation, chemical plants, and refineries. When you choose our Mechanical Boiler Feed Pumps, you can be sure that you are getting high-quality products that deliver optimal performance, value, and reliability. Contact us today to learn more about our Mechanical Boiler Feed Pumps and how we can help your business.
Introduction
D-type mechanical boiler feed pump is a single suction multistage segmented centrifugal pump for conveying clean water or other liquids physical and chemical properties similar to water. The temperature of the liquid shall not exceed 80 ℃. It has the characteristics of high efficiency, wide performance range, safe and stable operation, low noise, long service life, convenient installation, etc. It can also be used to transport hot water, oil, corrosive or abrasive media by changing the material and sealing form of pump flow parts and adding a cooling system.
D-type mechanical boiler feed pump is mainly used for industrial and urban water supply and drainage, pressurized water supply for high-rise buildings, garden sprinkler irrigation, fire pressurization, long-distance water supply, heating, bathroom and other cold and warm water circulation pressurization and equipment matching, especially for small boiler water supply.
Installation of mechanical boiler feed pump
1. Preparation before installation.
1) Check the water pump and motor.
2) Prepare tools and lifting machinery.
3) Check the foundation of the machine.
2. Installation sequence:
1) The complete set of mechanical boiler feed pump is transported to the site, and the motor has been installed with the base. It is not necessary to remove the water pump and motor when leveling the base.
2) Place the base on the foundation, pad wedge-shaped sizing block near the anchor screw, pad the base about 20 ~ 40mm high, and prepare to fill with water slurry after leveling.
3) Check the levelness of the base with a level gauge, tighten the anchor nut after leveling, and fill the base with cement slurry.
4) After 3 ~ 4 days of cement drying, check the levelness of primary water.
5) Wash and remove the dirt on the support plane of the base, the water pump foot and the motor foot;,, And put the boiler pump and motor on the base.
6) Adjust the pump shaft level, properly tighten the nut after leveling to prevent walking, install the motor after adjustment, and pad the non-level part with iron plate,
There is a certain clearance between the pump and the coupling.
7) Place the leveling ruler on the coupling and check whether the axis line of the water pump coincides with the axis line of the motor. If the table is not heavy, pad a thin sheet at the foot of the motor or pump to make the outer circle of the two couplings level with the leveling ruler, then take out several thin iron sheets of the pad, replace the iron sheet with a planed whole iron plate, and recheck the installation.
In order to check the installation accuracy, use feeler gauges at several opposite positions to measure the clearance between the two coupling planes. The difference between the maximum and minimum clearance around the coupling plane shall not exceed 0.3mm, and the difference below or around the center line of both ends shall not exceed 0.1mm.
Why choose us?
- Our company is committed to sustainability and reducing our impact on the environment.
- The company keeps to the operation concept 'scientific management, high quality and efficiency primacy, customer supreme for Mechanical Boiler Feed Pump.
- At our factory, we focus on producing Mutistage Water Pumps that are reliable, efficient, and durable.
- Our company will not forget our original intention and keep in mind our mission to actively create greater material and spiritual wealth for the society.
- Our company specializes in the manufacturing of Mutistage Water Pump products.
- With the continuous development of the market, our company has a rich range of Mechanical Boiler Feed Pump so far.
- Our Mutistage Water Pumps are backed by our commitment to quality assurance.
- The quality of our assets has been greatly improved, and our economic strength and operational vitality have been greatly enhanced.
- We have a reputation for quality and reliability that is unmatched in the industry.
- Continuous improvement is our self-discipline.
Hot Tags: mechanical boiler feed pump, China mechanical boiler feed pump suppliers, manufacturers, factory
You Might Also Like
Send Inquiry