Steps and precautions for the shutdown of the slurry pump
What are the shutdown steps and precautions of the slurry pump? The following editor will give you an introduction.
1) Steps to stop the slurry pump:
1. Close the vacuum gauge and pressure gauge valve.
2. Slowly close the outlet gate valve, and then stop the motor.
2) Precautions for slurry pump shutdown:
1. If the slurry pump stops the motor first and then closes the outlet valve, the high-pressure liquid in the extrusion pipe may backwash into the pump, causing the impeller to reverse at a high speed and cause damage.
2. If the pump is not used for a long time after the pump is stopped or the ambient temperature is lower than 0℃, the water in the pump should be discharged.
3. Generally, there is no gate valve on the pressure water pipeline of the axial flow pump, and it can be stopped directly.
4. For deep-well pumps, the water pump cannot be restarted immediately after stopping, because the water flow will produce an impact. Generally, it can be restarted after 5 minutes.