5 Motor Selection Steps, Easy To Learn And Use!

The type of load driven

This has to be reversed from the motor characteristics. The motor can be simply divided into DC motor and AC motor, and AC is divided into synchronous motor and asynchronous motor.

 

1, DC motor

The advantage of DC motors is that they can easily adjust the speed by changing the voltage, and can provide large torque. It is suitable for loads that need to adjust the speed frequently, such as mill in steel mills, hoist in mines, etc. But now with the development of frequency conversion technology, AC motors can also adjust the speed by changing the frequency. However, although the frequency conversion motor is not much more expensive than the ordinary motor, the frequency converter price occupies the main part of the whole equipment, so the DC motor has another advantage that it is cheap.

The disadvantage of DC motor is that the structure is complex, and any equipment as long as the structure is complex, it will inevitably lead to an increase in the failure rate. Dc motor compared with AC motor, in addition to the winding complex (field winding, commutator winding, compensation winding, armature winding), but also increase the slip ring, brush and commutator. Not only the manufacturer's process requirements are high, but also the later maintenance costs are relatively high. Therefore, the DC motor in industrial applications is in a gradual decline, but the transitional stage is still useful in the awkward situation. If the user has sufficient funds, it is recommended to choose the AC motor with frequency converter program, after all, the use of frequency converter also brings many benefits, this is not detailed.

 

 

2, asynchronous motor

The advantages of induction motor are simple structure, stable performance, easy maintenance and cheap price. And the manufacturing process is also the simplest, I have heard the old technician in the workshop said that the assembly of a DC motor, can complete the same power of two synchronous motors or four asynchronous motors, which can be seen. Therefore, asynchronous motors have been the most widely used in industry.

Induction motor is divided into squirrel cage type motor and wound type motor, the difference is the rotor. Squirrel-cage motor rotors are made of metal bars, copper or aluminum. The price of aluminum is relatively low, and China is a big aluminum mining country, which is widely used in occasions with low requirements. But the mechanical properties and electrical properties of copper are better than aluminum, and most of the rotors I contact are made of copper. The reliability of squirrel cage motor is much higher than that of winding rotor motor after solving the problem of broken row in the process. The disadvantage of the rotor is that the torque obtained by cutting the magnetic inductance line in the rotating stator magnetic field is small, and the starting current is large, which is difficult to meet the requirements of large starting torque load. Although increasing the motor core length can obtain more torque, but the force is very limited. The wound motor electrified the rotor winding through the slip ring when starting, forming a rotor magnetic field, which moves relative to the rotating stator magnetic field, so that the torque is greater. In the starting process, the water resistance is connected in series to reduce the starting current, and the water resistance is controlled by a mature electronic control device to change the resistance value with the starting process. Suitable for rolling mill, elevator and other loads. Because the winding asynchronous motor relative to the squirrel cage motor increases the slip ring, water resistance, etc., the overall equipment price has a certain increase. Compared with the DC motor, the speed range is relatively narrow and the torque is relatively small, and the corresponding value is also low.

However, the induction motor creates a rotating magnetic field by energizing the stator winding, and the winding is an inductive element that does not do work, so it must absorb reactive power from the power grid, which has a great impact on the power grid. Intuitive experience when a high-power inductive electrical appliance is connected to the power grid, the power grid voltage drops, and the brightness of the lamp decreases. Therefore, the power supply bureau will have restrictions on the use of asynchronous motors, which is also a place that many factories must consider. Some large electricity users such as steel mills, aluminum plants, etc., choose to build their own power plants to form their own independent power grids to reduce the use of asynchronous motors restrictions. Therefore, if the asynchronous motor needs to meet the use of high-power load, it needs to be equipped with reactive power compensation device, while the synchronous motor can provide reactive power to the grid through the excitation device, and the greater the power, the more obvious the advantages of the synchronous motor, resulting in the synchronous motor stage.

 

 

3, synchronous motor

The advantages of synchronous motor in addition to the overexcited state can compensate for reactive power, but also include 1) synchronous motor speed strictly comply with n=60f/p, can accurately control the speed; 2) The operation stability is high, when the power grid voltage suddenly drops, the excitation system will generally force excitation to ensure the stable operation of the motor, and the asynchronous motor torque (proportional to the square of the voltage) will decrease significantly; 3) the overload capacity is larger than the corresponding asynchronous motor; 4) High operating efficiency, especially low speed synchronous motor.

Synchronous motor can not be started directly, need asynchronous start or frequency conversion start. Asynchronous start means that the synchronous motor is equipped with a starting winding similar to the asynchronous motor cage winding on the rotor, and the additional resistance of about 10 times the resistance value of the excitation winding is connected in series in the excitation loop to form a closed circuit, the stator of the synchronous motor is directly connected to the power grid, so that it starts according to the asynchronous motor, when the speed reaches the sub-synchronous speed (95%). The starting mode of removing the additional resistance; Frequency conversion startup is not detailed. Therefore, one of the disadvantages of synchronous motors is the need to add additional equipment for starting.

Synchronous motor is operated by excitation current, if there is no excitation, the motor is asynchronous. Excitation is a DC system added to the rotor, its rotation speed and polarity are consistent with the stator, if there is a problem with excitation, the motor will be out of step, can not be adjusted, trigger protection "excitation failure" motor trip. Therefore, the second disadvantage of synchronous motor is the need to increase the excitation device, which was directly supplied by the DC machine, and is now mostly supplied by thyristor rectifier. Still that old saying, the more complex the structure, the more equipment, the more points of failure, the higher the failure rate.

(Synchronous motor reference: Baidu Library > Professional Information > Engineering Technology > Power/Water "Synchronous motor Characteristics")

According to the performance characteristics of synchronous motor, its application is mainly in the lifting machine, mill, fan, compressor, rolling mill, water pump and other loads.

In summary, the principle of selecting the motor is that the motor performance meets the production machinery requirements, and the motor with simple structure, cheap price, reliable work and easy maintenance is preferred. In this respect, AC motors are better than DC motors, AC asynchronous motors are better than AC synchronous motors, and squirrel cage asynchronous motors are better than wound asynchronous motors.

 

For the production machinery with stable load and no special requirements for starting and braking, the ordinary squirrel cage asynchronous motor should be preferred, which is widely used in machinery, pumps, fans and so on.

Starting and braking are more frequent, requiring production machinery with large starting and braking torque, such as bridge cranes, mine elevators, air compressors, irreversible rolling machines, etc., should use winding asynchronous motors.

No speed regulation requirements, need constant speed or require improved power factor occasions, synchronous motors should be used, such as medium and large capacity pumps, air compressors, lifts, mills, etc.

The speed range is required to be more than 1∶3, and the need for continuous stable and smooth speed regulation of the production machinery, it is appropriate to use independent DC motor or squirrel cage asynchronous motor or synchronous motor with frequency control, such as large precision machine tools, gantry planer, rolling mill, hoist, etc.

Production machinery requiring large starting rotation and soft mechanical characteristics, using series excitation or compound DC motors, such as trams, electric locomotives, heavy cranes, etc.

 

Rated power

The rated power of the motor refers to the output power, that is, the shaft power, also known as the capacity size, which is the signature parameter of the motor. People often ask how big the motor is, generally not referring to the size of the motor, but to the rated power. It is the most important indicator to quantify the load capacity of the motor, and it is also the parameter requirement that must be provided when the motor is selected.

The principle of correct selection of motor capacity should be the most economical and reasonable determination of motor power under the premise that the motor is capable of producing mechanical load requirements. If the power is selected too large, the equipment investment increases, resulting in waste, and the motor often underload operation, efficiency and AC motor power factor is low; On the contrary, if the power is selected too small, the motor will run overloaded, resulting in premature motor damage.

There are three factors that determine the main power of the motor:

1) The heat and temperature rise of the motor, which is the most important factor in determining the power of the motor; 2) Allow short-term overload capacity; 3) The starting ability of the asynchronous squirrel cage motor should also be considered.

First of all, the specific production machinery calculates and selects the load power according to its heating, temperature rise and load requirements, and the motor pre-selects the rated power according to the load power, working system and overload requirements. After the rated power of the motor is pre-selected, it is also necessary to check the heating, overload capacity and starting capacity if necessary. If one of them is not qualified, the motor must be re-selected and then checked until all are qualified. Therefore, the work system is also one of the necessary requirements, if there is no requirement, the default is processed according to the most conventional S1 work system; The motor with overload requirement also needs to provide overload multiple and corresponding running time; When the asynchronous squirrel cage motor drives the fan and other large moment of inertia load, it is also necessary to provide the load moment of inertia and starting resistance moment curve to check the starting ability.

The above selection of rated power is carried out under the premise of a standard ambient temperature of 40 ° C. If the ambient temperature of the motor is changed, the rated power of the motor must be corrected. According to theoretical calculation and practice, when the ambient temperature is different, the power of the motor can be roughly increased or decreased according to the following table.

Therefore, areas with harsh climates also need to provide ambient temperature, such as India, where the ambient temperature needs to be checked according to 50 ° C. In addition, the high altitude will also have an impact on the motor power, the higher the altitude, the greater the motor temperature rise, the smaller the output power. And the motor used at high altitude also needs to consider the influence of corona phenomenon.

For the current electric motor power range on the market, I would like to list the company's performance table data for reference.

Dc motor: ZD9350 (mill) 9350kW

Asynchronous motor: Squirrel cage YGF1120-4 (blast furnace fan) 28000kW

Winding YRKK1000-6 (raw material mill) 7400kW

Synchronous motor: TWS36000-4 (blast furnace fan) 36000kW (test unit up to 40000kW)

Rated voltage

The rated voltage of the motor refers to the line voltage under the rated operating mode.

The choice of the rated voltage of the motor depends on the power supply voltage of the power system to the enterprise and the size of the motor capacity.

The choice of AC motor voltage level mainly depends on the power supply voltage level at the site of use. Generally, the low voltage network is 380V, so the rated voltage is 380V(Y or △ connection), 220/380V(△/Y connection), 380/660V(△/Y connection). Low-voltage motor power increases to a certain extent (such as 300KW/380V), the current is limited by the bearing capacity of the wire is difficult to do large, or the cost is too high. Need to increase the voltage to achieve high power output. The power supply voltage of the high-voltage grid is generally 6000V or 10000V, and there are also 3300V, 6600V and 11000V voltage levels abroad. The advantages of high voltage motor are large power and strong impact resistance; The disadvantage is that the inertia is large, and the starting and braking are difficult.

The rated voltage of the DC motor should also be matched with the power supply voltage. Generally 110V, 220V and 440V. Among them, 220V is the common voltage level, and the high-power motor can be increased to 600 ~ 1000V. When the AC power supply is 380V and the three-phase bridge thyristor rectifier circuit is used for power supply, the rated voltage of the DC motor should be 440V, and when the three-phase half-wave thyristor rectifier power supply is used, the rated voltage of the DC motor should be 220V.

 

 

Rated speed

The rated speed of the motor refers to the speed under the rated working mode.

The motor and the working machinery driven by it have their own rated speed. When choosing the speed of the motor, it should be noted that the speed should not be selected too low, because the lower the rated speed of the motor, the more its series, the larger the volume, the higher the price; At the same time, the speed of the motor should not be selected too high, because this will make the transmission mechanism too complex, and difficult to maintain.

In addition, when the power is constant, the motor torque is inversely proportional to the speed. Rated speed

The rated speed of the motor refers to the speed under the rated working mode.

The motor and the working machinery driven by it have their own rated speed. When choosing the speed of the motor, it should be noted that the speed should not be selected too low, because the lower the rated speed of the motor, the more its series, the larger the volume, the higher the price; At the same time, the speed of the motor should not be selected too high, because this will make the transmission mechanism too complex, and difficult to maintain.

In addition, when the power is constant, the motor torque is inversely proportional to the speed.

Therefore, if the starting and braking requirements are not high, a comprehensive comparison can be made with several different rated speeds from the initial investment of the equipment, the floor area and maintenance costs, and the rated speed is finally determined. For those who often start, brake and reverse, but the duration of the transition process has little impact on productivity, in addition to considering the initial investment, the speed ratio and the rated speed of the motor are mainly selected on the basis of the minimum quantity loss of the transition process. For example, the lifting machine requires frequent positive and negative rotation and the torque is very large, the speed is very low, the motor is large and expensive.

When the motor speed is high, it is also necessary to consider the critical speed of the motor. The motor rotor will vibrate during operation, the amplitude of the rotor increases with the increase of the speed, and the amplitude reaches a maximum value at a certain speed (that is, the commonly called resonance), and the amplitude decreases gradually with the increase of the speed after exceeding this speed, and is stable in a certain range, the maximum speed of the rotor amplitude is called the critical speed of the rotor. This speed is equal to the natural frequency of the rotor. When the speed continues to increase, the amplitude will increase when the speed is close to 2 times the natural frequency, when the speed is equal to 2 times the natural frequency, it is called the second critical speed, and so on, there are three and four critical speeds. If the rotor runs under the critical speed, there will be severe vibration, and the bending degree of the shaft will increase significantly, and the long-term operation will cause serious bending deformation of the shaft, or even break. The first-order critical speed of the motor is generally above 1500 RPM, so the conventional low-speed motor generally does not consider the impact of the critical speed. On the contrary, for the 2-pole high-speed motor, the rated speed is close to 3000 RPM, the effect needs to be considered, and the long-term use of the motor in the critical speed range needs to be avoided.

 

Generally speaking, the type of driving load, the rated power, rated voltage, and rated speed of the motor can be roughly determined. But if you want to optimally meet the load requirements, these basic parameters are far from enough. The parameters also need to be provided include: frequency, working system, overload requirements, insulation level, protection level, moment of inertia, load resistance curve, installation mode, ambient temperature, altitude, outdoor requirements, etc., according to the specific situation.

You Might Also Like